April 2008
PG03300001E For more information visit: www.eaton.com
16-19
Accessories & Modification Codes
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Accessories
A200 NEMA
Heater Selection
General Information on Heater Coil Selection
For maximum motor protection and compliance with Article
430-32 of the National Electrical Code, select heater coils
from the tables in this section on the basis of motor name-
plate full load current.
When the full load current is unknown, selection may be
made on the basis of average full load currents.
Caution — The average ratings could be high or low for a
specific motor and therefore selection on this basis always
involves risk. For fully reliable motor protection, select
heater coils on the basis of full load current rating as shown
on the motor nameplate.
Heater coils are rated to protect 40°C rise motors, and
open and drip-proof motors having a service factor of 1.15
where the motor and the controller are at the same ambient
temperature.
For other conditions:
1. For 50°C, 55°C, 75°C rise motors and enclosed motors
having a service factor of 1.0, select one size smaller
coil.
2. Ambient temperature of controller lower than motor by
26°C (47°F), use one size smaller coil.
3. Ambient temperature of controller higher than motor by
26°C (47°F), use one size larger coil.
Ultimate tripping current of heater coils is approximately
1.25 times the minimum current rating listed in the tables.
Table 16-60. Heater Selection — Type A and B Overload Relays,
Sizes 3 and 4
Table 16-61. Heater Selection — Type A and B Overload Relays,
Sizes 5 and 6
Note: Size 7 and Larger — Advise Full Load Current.
Size
Starter
Ambient
Compensated
Enclosed
Starters
Non-
compensating
Enclosed
Starters
Heater
(One Heater per
Catalog Number)
All Applications Catalog
Number
Full Load Current of Motor Amps
12.8 – 14.1
14.2 – 15.5
15.6 – 17.1
17.2 – 18.9
19.0 – 20.8
11.9 – 13.0
13.1 – 14.3
14.4 – 15.9
16.0 – 17.4
17.5 – 19.1
FH68
FH69
FH70
FH71
FH72
20.9 – 22.9
23.0 – 25.2
25.3 – 27.8
27.9 – 30.6
30.7 – 33.5
19.2 – 21.1
21.2 – 23.2
23.3 – 25.6
25.7 – 28.1
28.2 – 30.8
FH73
FH74
FH75
FH76
FH77
33.6 – 37.5
37.6 – 41.5
41.6 – 56.3
46.4 – 50
51 – 55
30.9 – 34.5
34.6 – 38.2
38.3 – 42.6
42.7 – 46
47 – 51
FH78
FH79
FH80
FH81
FH82
56 – 61
62 – 66
67 – 73
74 – 78
52 – 56
57 – 61
62 – 67
68 – 72
FH83
FH84
FH85
FH86
79 – 84
85 – 92
73 – 77
78 – 84
FH87
FH88
93 – 101 85 – 91 FH89
102 – 110
111 – 122
123 – 129
130 – 133
92 – 99
100 – 110
111 – 122
123 – 128
129 – 133
FH90
FH91
FH92
FH93
FH94
For Size 4 Starters
For Size 3 Starters
Compensated Overload Relay Heater (
One Heater per
Catalog Number)
Open Starter Enclosed Starter Catalog
Number
Full Load Current of Motor (Amps)
Size 5 (with 300/5 Current Transformers)
118 – 129
130 – 141
142 – 155
156 – 170
171 – 187
188 – 205
206 – 224
225 – 244
245 – 263
264 – 292
293 – 300
118 – 129
130 – 141
142 – 155
156 – 170
171 – 187
188 – 205
206 – 224
225 – 244
245 – 263
264 – 292
FH23
FH24
FH25
FH26
FH27
FH28
FH29
FH30
FH31
FH32
FH33
FH34
Size 6 (with 600/5 Current Transformers)
236 – 259
260 – 283
284 – 310
311 – 340
341 – 374
375 – 411
412 – 448
449 – 489
490 – 527
528 – 585
586 – 600
236 – 259
260 – 283
284 – 310
311 – 340
341 – 374
375 – 411
412 – 448
449 – 489
490 – 527
528 – 540
FH23
FH24
FH25
FH26
FH27
FH28
FH29
FH30
FH31
FH32
FH33
FH34
Seitenansicht 18