PG03300001E For more information visit: www.eaton.com
16-33
Accessories & Modification Codes
April 2008
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
Accessories
Lighting Contactors
Auxiliary Contact Location for
CN35/ECL
Auxiliary Contacts — Mounting Positions
The sketches below illustrate the maxi-
mum number of auxiliary contacts that
can be assembled to a contactor and
their locations in standard enclosures.
Table 16-97. Auxiliary Contact Mounting Positions
Available positions on contactors or starters other than what is factory installed.
When a pneumatic timer is mounted on contactor, only side mounted auxiliary contact positions
are available. The solid-state timer, when added, takes up side mounted auxiliary contact
position.
For 100 – 400A contactors, a base auxiliary contact must be added in position L1 before additional
contacts can be mounted.
Figure 16-15. Auxiliary Contact Location
Size Poles Available Mounting Positions

Open Type Type 1 Type 3R,
4X, 12
10 Ampere
20 – 60 Ampere
60 Ampere
60 Ampere
2 – 4
2 – 3
4
5
T1, L1, R1
T1, L1
T1, L1
T1, L1
L1
L1
L1, T1
L1, T1
L1, T1
L1, T1
100 Ampere
200 Ampere
300 Ampere
400 Ampere
2 – 3
2 – 3
2 – 3
2 – 3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
R2, R3, L1, L2, L3
L1
T1
L1
T1
R1
Front View
10 – 60A
Contactors
Top View
R1
100 – 400A
Contactors
Front
of Contactor
Left Side
of Contactor
L2
Aux.
Cont.
L3
Aux.
Cont.
R2
Aux.
Cont.
R3
Aux.
Cont.
L1
Base
Aux.
Cont.
R1
Base
Aux.
Cont.
Rear
Rear
Right Side
of Contactor
Pneumatic Timers —
Top Mounted for CN35/ECL
Pneumatic Timer
Attachment mounts on top of 10 – 60A
lighting contactors (top mounted aux-
iliary contacts can not be installed on
device when timer is used). Timer unit
has DPST timed contacts — circuits in
each pole must be the same polarity.
Units are convertible from OFF to ON
Delay or vice-versa.
Table 16-98. Pneumatic Timers
Table 16-99. Maximum Ampere Ratings
Solid-State Timers for CN35/ECL
Solid-State ON DELAY Timer — Side
Mounted on CN35 Freedom Series Lighting
Contactors through 60A
This timer is
designed to be
wired in SERIES
with the load
(typically a coil).
When the START
button is pushed
(power applied to
timer), the ON DELAY timing function
starts. At the completion of the set tim-
ing period, timer and series wired load
will both be energized.
Table 16-100. Product Selection — Mounted
Timer
Add operating voltage Suffix to Catalog
Number. A = 120V, B = 240V, E = 208V
Rated .5 ampere pilot duty — not to be used
on larger contactors.
Terminal connections are quick connects
only. Two per side.
Timing Range Catalog Number
.1 to 30 Seconds
10 to 180 Seconds
C320TP1
C320TP2
Description Volts AC
120 240 480 600
Make
Break
30.0
3.0
15.0
1.5
7.5
0.75
6.0
0.6
Timing Range Catalog
Number

.1 – 1.0 Seconds
1 – 30 Seconds
30 – 300 Seconds
5 – 30 Minutes
C320TDN1_
C320TDN30_
C320TDN300_
C320TDN3000_